Halogen-free fire-retardant |
|
H07 Z-R/H07 ZK |
 |
Construction
Conductor : stranded bare copper (H07 Z-R) flexible bare copper (H07
Z-K)
Insulation : halogen free polymer compound
Properties
Halogen free
Flame retardant (EN 60332-1, IEC 60332-1)
Low smoke generation
No emission of corrosive gases
Service temperature: +5 ... +90°C
Min. bending radius: 4 x D |
|
2XH
0.6/1 kV
|
|
Construction
Copper conductor
XLPE insulation, core colours acc. to HD 308
Common core covering
Halogen free thermoplastic outer sheath
Properties
Max. admissible conductor temperature: 90°C
Service temperature: - 20 ... + 90°C
Min laying temperature: - 5°C
Min. bending radius:
Multicore: 12 x D
Singlecore: 15 x D
Fire retardant acc. to IEC 60332-3 cat. C
Low smoke density acc. to IEC 61034-1+2
Corrosivness of combustion gases acc. to IEC 60754-2
|
|
2XR(AL)H 0.6/1 kV
|
|
Construction
Copper conductor
XLPE insulation
Core covering
Armour: Aluminium wires
Halogen free thermoplastic outer sheath
Properties
Max. admissible conductor temperature: 90°C
Service temperature: - 20 ... + 90°C
Min laying temperature: - 5°C
Min. bending radius: 15 x D
Fire retardant acc. to IEC 60332-3 cat. C
Low smoke density acc. to IEC 61034-1+2
Corrosivness of combustion gases acc. to IEC 60754-2
|
|
2XHRH 0.6/1 kV
|
|
Construction
Copper conductor
XLPE insulation, core colours acc. to HD 308
Common core covering
Halogen free thermoplastic inner sheath
Armour: galvanized steel wires
Halogen free thermoplastic outer sheath black
Properties
Max. admissible conductor temperature: 90°C
Service temperature: - 20 ... + 90°C
Min laying temperature: - 5°C
Min. bending radius: 12 x D
Fire retardant acc. to IEC 60332-3 cat. C
Low smoke density acc. to IEC 61034-1+2
Corrosivness of combustion gases acc. to IEC 60754-2
|
|
2XHBH 0.6/1kV |
 |
Construction
Copper conductor
XLPE insulation, core colours acc. to HD 308
Common core covering
Halogen free thermoplastic inner sheath
Armour: 2 layers of galvanized steel tape
Halogen free thermoplastic outer sheath black
Properties
Max. admissible conductor temperature: 90°C
Service temperature: - 20 ... + 90°C
Min laying temperature: - 5°C
Min. bending radius: 12 x D
Fire retardant acc. to IEC 60332-3 cat. C
Low smoke density acc. to IEC 61034-1+2
Corrosivness of combustion gases acc. to IEC 60754-2 |
|
2XSH 0.6/1kV |
 |
Construction
Copper conductor
XLPE insulation
Common core covering
Copper tape screen
Outer sheath black
Properties
Max. admissible conductor temperature: 90°C
Service temperature: - 20 ... + 90°C
Min laying temperature: - 5°C
Min. bending radius: 12 x D
Fire retardant acc. to IEC 60332-3 cat. C
Low smoke density acc. to IEC 61034-1+2
Corrosivness of combustion gases acc. to IEC 60754-2 |
|
Halogen-free fire-resistant |
|
m2XH 0.6/1kV |
 |
Construction
Copper conductor
Mica-tape
XLPE insulation, core colours acc. to HD 308
Common core covering
Halogen free thermoplastic outer sheath
Properties
Max. admissible conductor temperature: 90°C
Service temperature: - 20 ... + 90°C
Min. laying temperature: - 5°C
Min. bending radius:
Multicore: 12 x D
Singlecore: 15 x D
Fire retardant acc. to IEC 60332-3 cat. C
Fire resistant acc. to IEC 60331
Low smoke density acc. to IEC 61034-1+2
Corrosiveness of combustion gases acc. to IEC 60754-2 |
|
m2XHRH 0.6/1kV |
 |
Construction
Copper conductor
Mica-tape
XLPE insulation, core colours acc. to HD 308
Common core covering
Halogen free thermoplastic inner sheath
Armour: galvanized steel wires
Halogen free thermoplastic outer sheath
Properties
Max. admissible conductor temperature: 90°C
Service temperature: - 20 ... + 90°C
Min. laying temperature: - 5°C
Min. bending radius: 12 x D
Fire retardant acc. to IEC 60332-3 cat. C
Fire resistant acc. to IEC 60331
Low smoke density acc. to IEC 61034-1+2
Corrosiveness of combustion gases acc. to IEC 60754-2 |