EAC 01 |
272049 |
 |
1-way F-type tap 8,5 dB,
5-1000 MHz, isolating capacitators on in and outputs, screening
class A acc. to CENELEC EN 50083 |
|
EAC 02 |
272053 |
 |
1-way F-type tap 12 dB,
5-1000 MHz, isolating capacitors on in and outputs, screening
class A as per CENELEC EN 50083-2 |
|
EAC 03 |
272054 |
 |
1-way F-type tap 16 dB,
5-1000 MHz, isolating capacitors on in and outputs, screening class
A acc. to CENELEC EN 50083-2 |
|
EAC 04 |
272055 |
 |
1-way F-type tap 20 dB,
5-1000 MHz, isolating capacitors on in and outputs, screening
class A acc. to CENELEC EN 50083-2 |
|
EAC 08 |
272855 |
 |
1-way F-type tap 11 dB,
5-2400 MHz, isolating capacitors on the tap outputs, screening
class A; remote feed up to 24 V/0,5 A |
|
EAC 09 |
272856 |
 |
1-way F-type tap 15 dB,
5-2400 MHz, isolating capacitors on the tap outputs, screening
class A; remote feeding to 24 V/0,5 A |
|
EAC 12 |
272327 |
 |
1-way tap 11 dB, 0,15-2150 MHz,
clamp connection, screening class A acc. to CENELEC EN 50083-2 |
|
EAC 16 |
272328 |
 |
1-way tap 14 dB, 0,15-2150 MHz,
clamp connection, screening class A acc. to CENELEC EN 50083-2 |
|
EAC 22 |
272329 |
 |
1-way tap 20 dB, 0,15-2150 MHz,
clamp connection, screening class A gem. CENELEC EN 50083-2 |
|
EAD 01 |
272344 |
 |
2-way F-type tap 8,5 dB;
5-1000 MHz, isolating capacitors on in/outputs, screening class A
acc. to CENELEC EN 50083-2 |
|
EAD 02 |
272345 |
 |
2-way F type tap 12 dB,
5-1000 MHz, isolating capacitors on in/outputs, screening class A
acc. to CENELEC EN 50083-2 |
|
EAD 03 |
272346 |
 |
2-way F-type tap 16 dB,
5-1000 MHz, isolating capacitors on in/outputs, screening class A
acc. to CENELEC EN 50083-2 |
|
EAD 04 |
272347 |
 |
2-way F-type tap 20 dB,
5-1000 MHz, isolating capacitors on in/outputs, screening class A
acc. to CENELEC EN 50083-2 |
|
EAD 08 |
272857 |
 |
2-way F-type tap 11dB, 5-2400 MHz,
isolating capacitors on the tap outputs, screening class A; remote
feed to 24 V/0,5 A |
|
EAD 09 |
272858 |
 |
2-way F-type tap 15dB, 5-2400 MHz,
isolarting capacitors on the tap outputs, screening class A; remote
feed to 24 V/0,5 A |
|
EAD 12 |
272348 |
 |
2-way tap 11dB, 0,15-2150 MHz,
clamp connection., screening class A acc. to CENELEC EN 50083-2 |
|
EAD 16 |
272349 |
 |
2-way tap 14dB, 0,15-2400 MHz,
clamp connection., screening class A acc. to CENELEC EN 50083-2 |
|
EAD 21 |
272307 |
 |
2-way tap 20dB, 0,15-2150 MHz,
clamp connection., screening class A acc. to CENELEC EN 50083-2 |
|
EAX 24 |
21610001 |
 |
4-way F-type end-tap 5-1000 MHz,
isolating capacitors on i/outputs, tap loss: 11,0/12,0 dB; screening
class A |
|
EAX 26 |
21610002 |
 |
6-way F-type tap 5-1000 MHz,
screen class A, isolating capacitors on in/outputs, Tap loss:
16,0 dB, thru' loss.: 5,7 dB |
|
EAX 28 |
21610003 |
 |
8-way F-type tap 5-1000 MHz,
screen class A, isolating capacitors on in/outputs, tap loss:
18,0 dB, thru' loss: 8,0 dB |
|
EBC 02 |
272606 |
 |
2-way F-type splitter, 5-1000 MHz,
isolating capacitors on in/outputs, screening class A CENELEC EN
50083-2 |
|
EBC 03 |
272607 |
 |
3-way F-type splitter, 5-1000 MHz,
isolating capacitors on in/outputs, screening class A CENELEC EN
50083-2 |
|
EBC 04 |
272608 |
 |
4-way F-type splitter, 5-1000 MHz,
isolating capacitors on in/outputs, screening class A CENELEC EN
50083-2 |
|
EBC 06 |
272635 |
 |
6-way F-type splitter, 5-1000 MHz,
isolating capacitors on in/outputs, screening class A CENELEC EN
50083-2 |
|
EBC 08 |
272636 |
 |
8-way F-type splitter, 5-1000 MHz,
isolating capacitors on in/outputs, screening class A CENELEC EN
50083-2 |
|
EBC 10 |
272859 |
 |
2-way F-type splitter 5-2400 MHz,
screening class A, earth clamp, remote feed max. 24 V/0,5 A (2
outputs), isolating diodes OUT->IN |
|
EBC 13 |
21610004 |
 |
3-way F-type spliter 5-2400 MHz,
screen class A, earth clamp, remote feed max. 24 V/0,5 A (3 output),
isolating diodes OUT->IN |
|
EBC 14 |
21610005 |
 |
4-way F-type splitter 5-2400 MHz,
screen class A, earth clamp, remote feed max. 24 V/0,5 A (4 output),
isolating diodes OUT->IN |
|
EBC 20 |
272627 |
 |
2-way splitter, 0,15-2150 MHz,
clamp connection, screen class A CENELEC EN 50083-2 |
|
EBC 24 |
272628 |
 |
2-way splitter, 0,15-2150 MHz,
clamp connection, screening class A CENELEC EN 50083-2, remote feed
to 24 V/0,5 A, with isolating diodes |
|
EBC 30 |
272629 |
 |
3-way clamp connection splitter,
0,15-2150 MHz, screening class A CENELEC EN 50083-2 |
|
EBI 24 |
273282 |
 |
T-connector TV, 4-862 MHz, Input:
1 x IEC (f), Outputs: 2 x IEC-(m), Splitting loss: 3,5 dB,
screening: VHF/UHF > 85/75 dB, screen class A |
|
EBL 44 |
272612 |
 |
4-way clamp connection splitter,
0,15-2150 MHz, screening class A CENELEC EN 50083-2 |
|
EMK 12 |
21210018 |
 |
F-compression connector; for
cables: LCD 90, LCD 95, LCD 99, LCD 111, screening factor: > 90 dB,
screen class A |
|
EMK 19 |
21210019 |
 |
F-compression connector; for
cables: LCM 14, LCM 17; screening factor: > 90 dB, screen class A |
|
ERD 21 |
272868 |
 |
Variable attenuator IEC,
0,15-2400 MHz, Range: 0,5-20 dB, screen class A |
|
ERD 23 |
272869 |
 |
Variable attenuator F,
47-2400 MHz, DC-passage, Range: 0,5-10 dB, screen class A |
|
ERE 01 |
274854 |
 |
F-type attenuation plug, 6 dB;
0-2400 MHz; remote feedable: 24 V/1A, screen class A |
|
ERE 02 |
274855 |
 |
F-type attenuation plug, 12 dB;
0-2400 MHz; remote feedable: 24 V/1A, screen class A |
|
ERZ 110 |
272670 |
 |
Cable equaliser 47-450 MHz,
F-connections, Equaliser range: 1-16 dB, steplessly settable, basic
loss: 1 dB (450 MHz) |
|
ERZ 111 |
272671 |
 |
Cable equaliser 47-606 MHz,
F-connections, Equaliser range: 1-16 dB, steplessly settable, basic
loss: 1 dB (606 MHz) |
|
ERZ 112 |
272672 |
 |
Cable equaliser 47-862 MHz,
F-connections, Equaliser range: 1-16 dB, steplessly settable, basic
loss: 1 dB (862 MHz) |
|
ERZ 60 |
272783 |
 |
Sat fixed equaliser 10 dB,
950-2400 MHz, Basic loss: 1 dB at 2400 MHz, screen class A |
|
ESC 30 |
21110013 |
 |
End antenna outlet 3-port;
47-68/125-862 a. 87,5-108 a. 950-2150 MHz; DC-passage over SAT;
Connection loss: Radio 2 dB, TV 1 dB, SAT 1 dB |
|
ESC 44 |
21110014 |
 |
Loop-thru' 2-port antenna outlet;
2 x 5-862 MHz; Connection loss: VHF/UHF 14,0 dB |
|
ESC 84 |
21110009 |
 |
End 2-port antenna outlet; 5-108
and 5-862 MHz; connection loss: FM 6,2 dB, TV 1,8 dB |
|
ESD 08 |
274197 |
 |
End antenna outlet 2-port;
0,15-2400 MHz; for two individual downleads; DC-passage; Connection
loss: VHF/UHF 0,2 dB, SAT 0,5 dB |
|
ESD 30 |
274209 |
 |
End antenna outlet 3-port; 2 x
4-862 a. 950-2400 MHz; DC-passage over SAT port; Connection loss:
VHF 3,5 dB, UHF 4 dB, SAT 1 dB |
|
ESD 32 |
274421 |
 |
End antenna outlet 3-port; 47-862
a. 950-2400 a. 47-2400 MHz; for two separate downleads; DC-passage
over 2 x SAT; conenction loss: 1 dB |
|
ESD 44 |
274418 |
 |
Loop-thru' 2-port antenna outlet;
2 x 4-2400 MHz; Connection loss: VHF/UHF 14,5 dB, SAT 15/16 dB |
|
ESD 52 |
274224 |
 |
Loop-thru' 2-port antenna outlet;
2 x 47-2400 MHz; DC-passage over TV/SAT; Connection loss: VHF/UHF
14,5 dB, SAT 15 dB |
|
ESD 64 |
274198 |
 |
Loop-thru' 2-port antenna outlet;
4-68 / 118-862 a. 87-108 MHz; connection loss: FM 10 dB, VHF/UHF
8 dB |
|
ESD 84 |
274425 |
 |
End 2-port antenna outlet; 2 x
4-2400 MHz; DC-passage over TV/SAT; connection loss: VHF/UHF 3,8 dB,
SAT 4,3 dB |
|
ESD 85 |
274426 |
 |
End 2-port antenna outlet;
0,15-30/87-108 a. 47-68/118-2400 MHz; DC-passage over TV/SAT;
connection loss: AM/FM 7/1 dB, VHF/UHF/SAT 1 |
|
ESE 10 |
274233 |
 |
Loop-thru' 2-port antenna outlet;
2 x 4 -2400 MHz; Double directional coupler; Connection loss:
VHF/UHF 11 dB, SAT 11 dB |
|
ESM 20 |
21110008 |
 |
Modem end 3-port ant. outlet;
Modem: 5-862 MHz; TV: 47-68/111-862 MHz; FM.: 87,5-108 MHz;
connection loss: 4 dB |
|
ESM 30 |
274429 |
 |
Modem end 3-port ant. outlet;
Modem: 5-862 MHz; TV: 80-862 MHz; FM: 80 - 862 MHz; connection loss:
6 dB |
|
ESM 31 |
274430 |
 |
Modem thru' 3-port ant. outlet;
Modem: 5-862 MHz; TV: 80-862 MHz; FM: 80-862 MHz; connection loss:
14 dB |
|
ESM 32 |
21110010 |
 |
Modem thru' 3-port antenna outlet;
Modem: 5-862 MHz; TV: 80-862 MHz; FM: 80-862 MHz; connection loss:
10 dB |
|
ESM 40 |
274456 |
 |
Modem end 3-port ant. outlet;
selective; Modem: 5-862 MHz; TV: 111-862 MHz; FM: 87-108 MHz;
connection loss: 3,5-4,5 dB, Ret. path: 1 dB |
|
ESM 41 |
274457 |
 |
Modem thru' 3-port ant. outlet;
selective; Modem: 5-862 MHz; TV: 111-862 MHz; FM: 87-108 MHz;
connection loss: 13,5-15 dB |
|
ESM 42 |
274458 |
 |
Modem thru' 3-port ant. outlet;
selective; Modem: 5-862 MHz; TV: 111-862 MHz; FM: 87-108 MHz;
connection loss: 10-11,5 dB |
|
EST 20 |
274230 |
 |
Ant. outlet add-on to combine
telephone/data stream nets with Kathrein ant. outlets; 2 x RJ 45
connections (1 x telephone, 1 x 10 Base T) |
|
ESU 32 |
21110005 |
 |
Loop-thru' 3-port outlet for
UFOmicro systems; 87-108 a. 47-68/118-862 a. 950-2150 MHz;
DC-passage over SAT; connection loss: FM 11 dB, |
|
ESU 33 |
21110012 |
 |
Loop-through outlet single cable
system; 3-port; 87-108 a. 47-68/118-862 a. 950-2150 MHz; DC-pass.
over SAT port; Connection loss: 10 dB (FM 11 dB) |
|
ESU 34 |
21110011 |
 |
End antenna outlet single cable
system; 3 port; 87-108 a. 47-68/118-862 a. 950-2150 MHz; DC-pass.
over SAT port; Connection loss: 0,5-1 dB |
|
ESZ 44 |
274318 |
 |
Central cover plate, universally
usable, 55 x 55 mm, Pearl white, RAL 1013 |
|
ESZ 50 |
274226 |
 |
On-wall outlet frame; suitable for
cover plates ESZ 52/53/54; 82 x 82 mm; pure white, RAL 9001 |
|
ESZ 52 |
274227 |
 |
Cover plate 2-port; 80 x 80 mm;
white, RAL 9001 |
|
ESZ 53 |
274228 |
 |
Cover plate 3-port; 80 x 80 mm;
white, RAL 9001 |
|
ESZ 54 |
274453 |
 |
Cover plate 3-port for modem
outlet; printed with TV/Data/R; 80 x 80 mm; white, RAL 9001 |
|
ETG 15 |
274779 |
 |
Receiver connection cable 1,5 m;
F-male/F-male |
|
ETG 30 |
274778 |
 |
Receiver connection cable 3,0 m;
F-male/F-male |
|
ETH 15 |
274761 |
 |
Receiver connection cable 1,5 m,
IEC angled plug |
|
ETH 30 |
274762 |
 |
Receiver connection cable 3,0 m;
IEC angled plug |
|
ETH 50 |
274763 |
 |
Receiver connection cable 5,0 m,
IEC angled plug |
|
KAZ 11 |
507205 |
 |
Voltage surge protection,
5-3000 MHz, F-connect.; remote feeding < 24 V DC/2 A; test socket
-20 dB; protects against transient over-voltage |
|
KAZ 12 |
21810002 |
 |
Lightning arrester; general
protection against higher discharged currents; 5-2400 MHz; F
connectors; remote feeding < 60 V/2 A |
|
VCN 20 |
230243 |
 |
Distribution amplifier 10 dB;
47-862 MHz; to plug on antenna outlets; with plug-psu; 3 outputs:
TV/Radio/output amplified (F connector) |
|
ZAW 13 |
21410012 |
 |